Hisurp Double Coil Air Conditioner is a dedicated advanced air conditioning system designed for high reliability scenarios. By configuring two independent cold sources, it can achieve continuous cooling and redundancy throughout the year and is widely used in critical infrastructure environments.
Double Coil Air Conditioner integrate two cooling sources (usually mechanical refrigeration + natural
cooling) on the
basis of traditional precision air conditioners. They can automatically switch or operate in coordination
according to
environmental conditions to ensure zero-risk operation of the equipment.
Application
Double Coil Air Conditioners are primarily used in locations with extremely high environmental requirements:
Data Centers (IDC)
Communication Base Stations (5G Core Rooms)
Power Dispatch Centers
Petrochemical Control Rooms
Financial Data Centers
Features
Hisurp offers specific Double Coil Air Conditioners provided with two independent cooling sources for critical
applications where the discontinuity of equipment operation is not acceptable.
High operational safety
Sometime the main cooling source may be insufficient to guarantee suitable environmental conditions. This may be due to
an overload of the system, possible seasonal closures or any type of emergency. A reduction in the Double Coil Air
Conditioner cooling capacity can lead to great instability in the system, even in the presence of redundancy or Smart
Net systems.
To avoid these problems, specific twin sources units have been developed providing a second source of cooling, complete
with its own control valve and independent from the primary one.
A safe, flexible system
The Dual Power system is very flexible and allows three different types of systems.
Chilled water + direct expansion twin sources
The chilled water primary source of the unit is connected to a building chiller or to district cooling, whereas the
secondary, emergency, and direct expansion one is connected to remote air or in-built water condensers (1).
Direct expansion + chilled water two sources
The direct expansion primary source of the Double Coil Air Conditioner is connected to remote air or in-built water
condensers, whereas the secondary, emergency,and water one is connected to a dedicated chiller, to a groundwater /
aqueduct water distribution network or to district cooling (2).
Chilled water + chilled water two sources
Both sources of the Double Coil Air Conditioner are chilled water coils.The primary one is normally connected to a
building chiller or to district cooling. The emergency source can be connected to a dedicated chiller or a groundwater /
aqueduct water distribution network (3).