Ningbo Hicon Industry Co., Ltd.
Ningbo Hicon Industry Co., Ltd.
Products
Air Handler Unit
  • Air Handler UnitAir Handler Unit

Air Handler Unit

Hisurp's DX Air Handler Unit is a modular air handling solution designed for projects that require direct expansion cooling combined with flexible air treatment functions. Compared with chilled water systems, a Direct Expansion AHU works directly with refrigerant-based cooling, making it suitable for applications where a chilled water plant is not preferred or where system simplicity and independent operation are important.
Built on Hisurp’s modular combination air handling platform, this unit can be configured with multiple functional sections including filtration, fresh air mixing, cooling, heating, humidification, silencing, heat recovery, and purification. It is ideal for industrial and commercial projects that demand customizable air-side design with refrigerant-based cooling.

What Is a DX Air Handler Unit?

A DX AHU is an air handling unit that uses direct expansion refrigerant coils instead of chilled water coils. Refrigerant evaporates directly inside the cooling coil to absorb heat from the passing air. This type of AHU is commonly used in systems that require:

  • Independent air treatment zones
  • Simplified cooling infrastructure
  • Packaged or split refrigerant systems
  • Lower dependence on central chilled water plants
  • Flexible installation for commercial or industrial projects

For many applications, direct expansion AHUs provide a compact and efficient solution for air cooling and conditioning.

Key Product Features

Modular Design for Project Flexibility

The unit adopts standard modular dimensions, allowing width and height changes according to project conditions. Functional sections can be freely combined to meet site-specific air handling requirements.

Durable Double-Skin Cabinet

The cabinet uses a robust frame structure and double-skin insulated panels. The outer panel uses quality coated steel plate, while the inner plate can be galvanized steel, aluminum-zinc steel, or stainless steel depending on application demand.

Benefits include:

  • Strong thermal insulation
  • Low leakage
  • Anti-corrosion performance
  • Structural strength
  • Convenient maintenance

Efficient Direct Expansion Coil Arrangement

The DX coil is designed for effective refrigerant-based heat exchange and can be integrated into different section combinations. The cabinet structure supports easy access for maintenance and proper connection of refrigerant piping during installation.

Easy Transport and On-Site Assembly

The modular and detachable construction makes transportation and field installation more convenient, especially for large mechanical rooms and difficult access sites.

Functional Section Options

Hicon’s Direct Expansion AHU can be tailored with multiple functions, including:

  • fresh air section
  • return air section
  • mixing section
  • damper control section
  • primary and medium filtration
  • activated carbon filtration
  • humidification section
  • silencer section
  • electric heating section
  • ultraviolet sterilization section
  • ozone sterilization section
  • electronic air purification section
  • heat recovery section
  • fan section

This flexible structure allows the DX AHU to serve a broad range of project requirements.

Functional Section Options

Hicon’s DX Air Handler Unit is suitable for:

  • pharmaceutical production areas
  • food processing facilities
  • cosmetics workshops
  • electronics assembly spaces
  • tobacco factories
  • office HVAC systems
  • hotels and commercial buildings
  • shopping centers
  • public building ventilation systems
  • retrofit projects without chilled water networks

Because it uses direct expansion cooling, the unit can be especially attractive for projects where a refrigerant-based system is easier to deploy than a chilled water system.

Our Advantages

Customized parameter, outlook, color etc.

Customized parameter, outlook, color etc.

Low temperature kits optional

Low temperature kits optional

Environmentally friendly refrigerant

Environmentally friendly refrigerant

Fix frequency & variable frequency optional

Fix frequency & variable frequency optional

The Belt and Road co-operation partners

The Belt and Road co-operation partners

National-class (CNAS) labs and testing rooms

National-class (CNAS) labs and testing rooms

Contact Hicon for DX AHU Selection

If your project requires a DX AHU with flexible functions and modular design, Hicon can help you configure a suitable solution based on airflow, cooling demand, ESP, filtration requirement, and installation conditions.
Contact us today for technical support and quotation

Hot Tags: Air Handler Unit Manufacturer
Related Category
Send Inquiry
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
Reject Accept