In system of Hisurp Chilled Water Precision Air Conditioner, medium to transport heat generated inside data center to outside environment is chilled water. Chilled water having temperature of 5 to 7℃ supplied to indoor AC unit from Chiller.
Chilled Water Precision Air Conditioner is especially suitable for the power plant data center, control plant
data
center and other areas which need to be accurately controlled in terms of temperature and humidity, and it
is also
suitable for the other occasions which need year-round cooling.
Features
Reduction of compressor running time during the cold season;
EER up to 6.0 and above;
The data center is not contaminated by outdoor air;
Compressor cooling stops when full free cooling starts, reducing noise in the room;
Extending the life of unit;
Avoids possible malfunctions due to start-up of the compressor in low temperature;
Independent humidification system, high-precision Chilled Water Precision Air Conditioner controller.
Main Spare Parts of Chilled Water Precision Air Conditioner
Motor
IP54, Standard DIN VDE 0470
Insulation F Standard DIN VDE 0530
Sensor
Small and light
High measurement accuracy
Quick response
Good long-term stability
Humidifier
Clean vapour, the cleanest humidification
Presicely control humidifying capacity with a sensor
Optional electrode humidifier and steam humidifier
Free Cooling (optional)
Chilled Water Precision Air Conditioner utilizes the outdoor cooling source to transfer indoor heat to outdoor heat
exchanger.
When the indoor temperature is higher than set temperature of Chilled Water Precision Air Conditioner, the control
system will send a signal to the Chilled Water Precision Air Conditioner, glycol unit and water pump, to make the
air-cooling unit stop, let the glycol unit and water pump start, also the outdoor free cooling heat exchanger is
energized. The outdoor temperature sensor feeds back the temperature signal of the outdoor free cooling heat exchanger
to the outdoor fan. If the temperature of the outdoor free cooling heat exchanger is higher than the set temperature,
the fan will start unit, the temperature is lower than the set temperature.
When the indoor temperature is lower than set temperature of Chilled Water Precision Air Conditioner, the control system
will send a signal to stop the pump and cut off the power of outdoor fan. So as to ensure indoor constant temperature.
Under the condition of constant temperature, constant humidity and cleanliness of the data center, the unit achieves the
purpose of energy saving and consumption reduction.