E-House Air Conditioner
A brief introduction of HISURP CAC series E-house Air Conditioners

Energy Storage Air Conditioner

Telecom Air Conditioner

Rooftop Air Conditioner
As seasoned Rooftop Air Conditioner manufacturers, Hisurp is a reputable Chinese factory offering CE-certified products.
Adopting integrated design, the unit combines cooling, heating, ventilation and filtration. It runs steadily, installs effortlessly and cuts energy consumption by 20%-30%, backed by 15-year service life.
Customized solutions and complete after-sales support are accessible. We supply goods in bulk with competitive prices, perfectly fitting diverse building scenarios, serving as your preferred purchasing option.

Rooftop Ac
Hisurp Rooftop AC adopts adaptive energy-saving control and DC frequency conversion motor. Ideal for workshops and computer rooms needing uninterrupted cooling, it utilizes free cooling to achieve up to 58% comprehensive energy saving. The unit operates steadily amid -40℃ to 48℃ wide temperature scope. Owning authoritative Certification of ISO9001, every unit undergoes full power-on test before shipment, guaranteeing durable stable performance and eco-friendly energy efficiency.

Packaged Air conditioner
Hisurp delivers dependable Packaged Air Conditioner with stable factory production and solid quality assurance. Customized packaged air conditioner supports adjustable cooling capacity, size and functions, fitting multiple application occasions. All products come with 12-month warranty, thoughtful after-sales support to cut purchase risks. Featuring energy efficiency, low noise and easy installation, strictly inspected units are premium cooling choices.

Packaged Unit
Hisurp supplies advanced Packaged unit as all-in-one HVAC equipment. It integrates core components into compact body, realizing fast installation and effortless maintenance. Sturdy quality verified by strict factory tests ensures steady operation, energy conservation and long service lifespan. Adaptable to harsh working conditions with strong anti-interference capability, it cuts daily power consumption and operating expenses. The integrated structure saves occupied space and shortens construction period, perfectly meeting heating and cooling demands of commercial, industrial and public venues.

Air Cooled Precision Air Conditioner

Water Cooled Precision Air Conditioner

Dual Coil Precision Air Conditioner

Air Cooled Scroll Chiller

Air Cooled Screw Chiller

Water Cooled Scroll Chiller

Water Cooled Screw Chiller

Corrosion-Resistant Air Conditioner
Hisurp Corrosion-Resistant Air Conditioner is a type of air conditioning system designed to be enhanced for corrosive environments (especially marine, chemical, salt spray, and high humidity environments).

Earthquake-Resistant Air Conditioner
Based on the design concept of "prevention first", Hisurp earthquake-resistant air conditioner uses a series of advanced measures that exceed conventional standards to minimize the risk of damage to the air conditioning system caused by earthquakes, and ensure environmental control and business continuity in critical locations.

Magnetic-Resistant Air Conditioner
Hisurp Magnetic-Resistant Air Conditioner is an industrial air conditioner designed specifically for strong magnetic field environments. Through a multi-layer shielding system, it ensures stable and durable operation of the unit in a magnetic field environment of ≥2000GS.
E-Room Air Conditioner is widely used in various industrial fields such as steel plants, chemical plants, paper mills, printing plants, power plants, substations, food factories, garment factories, and microelectronics factories, as well as various electrical control rooms.
The standard operating temperature range for E-Room Air Conditioner dry bulbs is 21-35℃ (indoor) /
21-45℃ (outdoor);
The high-temperature type, when used with the spraying solution, allows outdoor temperatures up to
60℃;
The ultra-high temperature R142b E-Room Air Conditioner can reach up to 80℃.
1. The indoor unit is relatively thin, while the outdoor unit is heavy, requiring a foundation
for
installation;
2. The indoor unit's noise level is slightly lower, unaffected by the compressor;
3. The main control components are located in the outdoor unit, with compact piping. It is
generally
recommended to
run the power supply through the outdoor unit;
4. The compressor's oil return is significantly affected by the installation height and distance
of
the outdoor unit.
Strict piping return processes are required, and longer pipe distances result in greater cooling
loss;
5.The outdoor unit's computer board and electrical components have high requirements for dust,
moisture, high
temperature, and corrosion protection, leading to a slightly higher failure rate.
1. The indoor unit is slightly thicker, while the outdoor unit is lighter, making installation
simpler, with fewer
restrictions, and a simpler oil return process.
2. Indoor unit noise is slightly higher due to the compressor.
3. Main control components are located in the indoor unit, resulting in a compact layout. The
indoor
unit powers the
main unit, making management and maintenance convenient.
5. Smaller diameter copper pipes and wiring specifications reduce overall project cost.
6. All connecting pipes are high-pressure pipes, resulting in low resistance loss, good oil
return,
fewer restrictions
on long pipe distances and large height differences, and less cooling loss.
7. The outdoor unit has no computer board, electrical components, or compressor, eliminating
concerns about dust,
moisture, high temperatures, and corrosion, and resulting in a low component failure rate.
E-Room Air Conditioners are installed in steel factory’s electric room.



Selecting the correct capacity is essential for stable performance and energy efficiency.
Proper sizing ensures the E-Room Air Conditioner operates efficiently without overloading or short cycling.
Poor cooling performance usually comes from operational or environmental factors:
Regular inspection and preventive maintenance are key to keeping the E-Room Air Conditioner stable in industrial environments.
Filter maintenance is critical for airflow and cooling efficiency:
In high-dust environments such as steel plants or paper mills, more frequent cleaning is recommended.
Evaporator icing can occur under abnormal operating conditions:
If freezing occurs repeatedly, technical inspection is required to avoid damage to the E-Room Air Conditioner system.